Table 4-4 spi flash or sd card selection, Table 4-5 remote control selection – ADLINK aTCA-N700 User Manual

Page 20

Advertising
background image

aTCA-N700 HW Users Guide

20

2) SW4:
SW4 can switch between an SPI flash boot or an SD Card boot.

Table 4-4 SPI Flash or SD Card selection

SW NO

Mode

Setting

Figure

SPI Flash

1 OFF
2 ON
3 ON
4 OFF

SW2

SD Card

1 ON
2 OFF
3 OFF
4 ON




3) SW7:
SW7 supports remote booting from the LMP. Top (F) or Bottom (S) is supported
respectively

.


Table 4-5 Remote control selection

SW NO

Mode

Setting

Figure

Normal operation

1 OFF
2 ON
3 OFF
4 ON

F_OCTEON

Remote Control

select

1 ON
2 OFF
3 OFF
4 ON

SW7

S_OCTEON

Remote Control

select

1 OFF
2 ON
3 ON
4 OFF


Advertising