Lcl errors – Echelon Neuron User Manual

Page 20

Advertising
background image

12

Communication Parameter Calculator Errors (LCL)

LCL Errors

Table 5 lists the LCL error codes.

Table 5. LCL Error Codes

LCL#

Description

1

Can not compute communication port control byte. [LCL#1]

The tool failed to compute the communication port (CP) control byte.

Verify that your standard transceiver database (stdxcvr.xml) has not been

corrupted. Re-install the product and choose the Repair option when

prompted.

2

Unrecognized encoded clock rate value <id> [LCL#2]

An unrecognized encoded value was for clock speed (5 for 10MHz, 6 for

20MHz, and so on). Re-install the product and choose the Repair option

when prompted.

3

The transceiver's general purpose data record seems malformed: <gp data>

[LCL#3]

The xcvr_gp_data in STDXCVR.XML seems malformed. Verify that your

standard transceiver database (stdxcvr.xml) has not been corrupted. Re-

install the product and choose the Repair option when prompted.

4

The device's clock rate (encoded value <id>) and the transceiver's

communication rate (encoded value <id>) result in an invalid communication

clock divider value. One of the two input rates might be invalid [LCL#4]

The device's clock rate and the transceiver's communication rate result in

an invalid communication clock divider value. One of the two input rates
might be invalid. See the error message for failure details. Try increasing

or lowering the Neuron clock speed.

5

Unable to determine <attribute> using transceiver <xcvr name> [LCL#5]

The aspect described as <attribute> cannot be computed as part of the
communication parameter calculations. Verify that your standard

transceiver database (stdxcvr.xml) has not been corrupted. Re-install the

product and choose the Repair option when prompted.

6

The transceiver requires a minimum clockrate which is higher than the device's

configured input clock speed. [LCL#6]

The target chip’s system clock speed for the MAC context is lower than the

required minimum for this transceiver. Choose a higher clock rate where

possible, or choose a different transceiver type.