Echelon Neuron User Manual

Page 27

Advertising
background image

Neuron Tools Errors Guide

19

LID#

Description

20

Error (non-file I/O) when writing XIF file

Refer to the error message for details about the failure cause. The error

message contains details such as “disk full,” or “file access denied”.

21

The xif32bin.exe utility returned an error, indicating failure when converting

XIF to XFB

The binary device interface file (.xfb extension) could not be created. Verify

that a previously existing binary device interface file is not write-protected.
Also make sure the XIF32Bin.exe utility, which is used to create the binary

device interface file, is available in a folder that is part of the system or

current user search path. By default, the utility can be found in your
LonWorks Bin folder.

22

An error occurred when reading a type info file (.NCT)

This is an internal error, possibly resulting from an earlier failure. The

.nct file is an intermediate file used by the LonTalk Interface Developer

utility. Re-run the LonTalk Interface Developer utility in Trace verbosity
mode and carefully examine the LonTalk Interface Developer utility

Summary window to determine the root cause of the failure.

23

An error occurred when reading a type info file (.NCT)

This is an internal error, possibly resulting from an earlier failure. The

.nct file is an intermediate file used by the LonTalk Interface Developer
utility. Re-run the LonTalk Interface Developer utility in Trace verbosity

mode and carefully examine the LonTalk Interface Developer utility
Summary window to determine the root cause of the failure. This error is

similar to LID#22, but refers to different internal software components.

24

Type info (.NCT) file seems corrupted

This is an internal error, possibly resulting from an earlier failure. The

.nct file is an intermediate file used by the LonTalk Interface Developer
utility. Re-run the LonTalk Interface Developer utility in Trace verbosity

mode and carefully examine the LonTalk Interface Developer utility

Summary window to determine the root cause of the failure.

25

Unexpected end of type info file (.NCT)

This is an internal error, possibly resulting from an earlier failure. The
.nct file is an intermediate file used by the LonTalk Interface Developer

utility. Re-run the LonTalk Interface Developer utility in Trace verbosity
mode and carefully examine the LonTalk Interface Developer utility

Summary window to determine the root cause of the failure.

26

Specified target language does not match an implemented code generator

Choose a different target host language.

Advertising