General installation recommendations installation, General mounting instructions – Hatteland Display 20 inch - HM 20T07 CMD User Manual

Page 15

Advertising
background image

15

IND100078-18

General Installation Recommendations

Installation

General mounting instructions

1: The useful life of the components of all Electronics Units generally decreases with increasing ambient temperature;

it is therefore advisable to install such units in air-conditioned rooms. If there are no such facilities these rooms

must at least be dry, adequately ventilated and kept at a suitable temperature.

2: This device is cooled by air flowing across the rear cover and air flowing through the ventilation holes. The cooling

must not be impaired by partial covering of the unit or by installation of the unit in a confined cabinet.

3: Units which are to be used on the bridge wing must be installed inside the “wing control console” protected against

the weather. In order to avoid misting of the viewing screen, a 25 ... 50 W console-heating (power depending on the

volume) is recommended.

4: When selecting the site of a display unit, the maximum cable lengths have to be considered.

5: The impairment of read-out from a display screen by direct light from lamps or the sun must be avoided. Rear

windows must be blacked out by means of roller blinds or Venetian blinds.

6: Disturbing reflections on the screen of a display caused by pilot lamps and illuminated signs must be prevented by

suitable measures (screening or relocating).

7: When a product is being installed, the surface base or bulkhead must be checked to ensure that it is flat in order to

avoid twisting of the unit when the fixing screws are tightened, because such twisting would impair mechanical

functions. Any unevenness should be compensated for by means of spacing-washers.

8: Transportation damage, even if apparently insignificant at first glance, must immediately be examined and be

reported to the freight carrier. The moment of setting-to-work of the equipment is too late, not only for reporting the

damage but also for the supply of replacements.

9: The classification is only valid for approved mounting brackets provided by Hatteland Display. The unit shall be

mounted stand-alone without any devices or loose parts placed at or nearby the unit. Any other type of mounting

might require test and re-classification.