Serial Communication (SCOM) Interface

Communication Interface

IND100084-8

Comm settings

The communication options are set by dip switches and jumpers, placed at the backside of the unit. These switches/

jumpers are protected behind a hatch mounted with four screws. Unscrew those, and remove the hatch. The commu-

nication settings and its switches are illustrated below.

Factory Default Settings

The factory defaults are based on the configuration when ordered. To configure the unit back to its factory defaults,

please contact your provider.

Reference

Part number

Description

Type

Additional information

JP1

1-2 MENU BRT CONTROL

2-3 ALWAYS ON

MENU LED Brightness and ON/OFF Control

Jumper

Removal of this jumper will

deactivate key backlight.

INV LED and Power LED will

still be active though.

JP2

1-3 SCOM-A1

SCOM-A1 BEEPER- TO CHGND

Jumper

JP2

2-4 SCOM-A1

SCOM-A1 COM1-9 VIA 100R TO CHGND

Jumper

JP3

OPEN COM1-1=NC

OPEN COM3-11=NC

COM1-1 and COM3-11 pin select

Jumper

COM2-1 = 5V (ALWAYS)

JP4

1-3 SCOM-A1

SCOM-A1 = COM1/2-4 OPEN OR VIA 100R TO CHGND

Jumper

JP4

2-4 SCOM-A1

SCOM-A1 = COM1/2-6 OPEN OR VIA 100R TO CHGND

Jumper

S3

COM1/2 RS-232

RS-232 supported ONLY

Switch

RS-232 SUPPORT ONLY!

S4

STRAIGHT TX/RX

COM1/2 Straight or Crossed(Switched) TX/RX select

Switch

S5

RS422 FULL DUPLEX

COM1/2 FULL(RS422) or HALF(RS485) operation

Switch

NOT SUPPORTED!

PROG_SEL

PROGRAM U5

Program Select for programming U5 via PBR header

Jumper

PROG_SEL

PROGRAM U12

Program Select for programming U12 via PBR header

Jumper

Communication Protocol

Communication mode

Backlight Config

Program Select

RS422 Full Duplex ON/OFF

SCOM Config #1

Program

Input Connector

SCOM Config #2

COM Config

SCOM Config #2