Hatteland Display 20 inch - HM 20T07 CMD User Manual

Page 65

Advertising
background image

65

Video Controller Interface Commands

Command Table

IND100103-1

n = 1-byte ascii-coded hex number, e.g., parameter value of 0x1 is represented by “1” (0x31).

nn = 2-byte ascii-coded hex number, e.g., parameter value of 0x1e is represented by “1”, “e” | “E” (0x31, x6e|0x4e).

Remarks:

1. Command 0xcd is only available for new units (05 May 2003 and after).

2. If the data sent to the controller is out of range, the controller will not set that value and there will be no

acknowledgement.

3. If the command sent to the controller is not available for that controller, there will be no acknowledgement.

4. The controller will respond to RS-232 command when the controller is in standby, no video input or normal

operating condition.

5. If the following parameters are changed through RS-232: Power Down Option, Exclusive/Priority,

Input Source, Video Input, the controller should change state according to the latest setting immediately.

Saving the user

default

0xd7

Saving all parameters to user

default value

“1” - successful.

Loading the user

default

0xd8

Loading all parameters to user

default value

“1” - successful.

Volume control -

left+right channel

0x80, “a” | “A”,

nn | “+” | “-” |

“r” | “R” |

“?”

Set audio (L+R) volume =

value/increment/decrement

Reset

Query

volume control

Volume control -

on/off (mute)

0x80, “m” | “M”,

“0” |

“1” |

“r” | “R” |

“?”

Disable audio output.

Enable audio output.

Reset

Query

“0” - audio off (muted).

“1” - audio on.

Other Control

Function

Command

Description

Acknowledge (if enabled)

Select video mode

0xc2, nn

Current vmode = nn.

Current video mode selected.

Auto-setup

0xc3

Start auto-setup of current

vmode.

“0” – fail.

“1” – successful.

Command

availability

0xc4, nn

Check whether a command is

available.

“0” – not available.

“1” – available.

Graphic horizontal

resolution enquiry

0xb7

Horizontal resolution (in pixels)

in 3 digit hex number

“nnn” = horizontal resolution

Graphic vertical

resolution enquiry

0xb8

Vertical resolution (in lines) in 3

digit hex number

“nnn” = vertical resolution

Graphic horizontal

sync frequency

0xb9

Horizontal sync frequency (in

units of 100Hz) in 3 digit hex

number

“nnn” = horizontal frequency

Graphic vertical

sync frequency

0xba

Vertical sync frequency (in units

of Hz) in 3 digit hex number

“nnn” = vertical frequency

OSD turn off

0xbd

Turn off the OSD.

“0” – fail.

“1” – successful.

Function

Command

Description

Acknowledge (if enabled)

Advertising