Hatteland Display 20 inch - HM 20T07 CMD User Manual

Page 22

Advertising
background image

Physical Connections - HM 20T07 xxx

22

IND100133-30

0 1

MAIN POWER TOGGLE SWITCH:

For AC models the main power toggle switch provide secure 100% power off which means no physical/electrical

connection between power input and power module is possible. This differ from the soft-power on/off button on the

front of the product which only sends a electronic remote power switch signal to the internal power electronics.

For DC models, the switch act as a single pole power switch, thus only disconnecting power and not cutting both

power lines. When connecting / disconnecting any cables, please make sure to set the switch to 0 (off).

DVI-I IN:

Connect your DVI cable to the DVI-I 29P Connector (female). Fasten the DVI cable to the connector and make sure

you don’t bend any of the pins inside the connector when connecting. The DVI-I connector can function as regular

RGB IN by using a DVI-I -> RGB/VGA cable. For pinouts, see PIN ASSIGNMENTS chapter.

R G B

RGB OUT: (RGB - Circular BNC connectors)

This will enable a clone image output of the picture being displayed on the unit via the RGB IN. Connect your BNC

cable to the 3 x BNC Connectors (female) and connect the opposite to your equipment. Make sure the connectors is

firmly fasten and that you do not switch around the separate signals/colors for: R(to red color cable),

G(to green color cable) and B(to blue color cable). Note: RGB output is only suitable for use with RGB Sync on Green

signals.

R G B G B

RGB IN: (RGBHV - Circular BNC connectors)

Connect your BNC cable to the 5 x BNC Connectors (female) connect the opposite to your equipment. Make sure the

connectors is firmly fasten and that you do not switch around the separate signal/colors for: R(to red color cable),

G(to green color cable), B(to blue color cable) H(to horizonal sync gray color cable) and V(to vertical sync black color

cable).