Hatteland Display 20 inch - HM 20T07 CMD User Manual

Page 55

Advertising
background image

55

Serial Communication (SCOM) Interface

Communication Interface

IND100084-1

Unit control command “MCC”

This command is used for communication with the video interface controller of the unit to allow remote command of

the unit’s setup parameters. The video controller commands are transmitted in the data field. See appendix for

complete list of controller commands. Please note that this feature is not supported by all video controllers / units.

For future products, it can not be guaranteed that all commands will still be available.

Note: Maritime Multi Computer (MMC) units do not have a video interface controller internally and the MCC command

is therefore not supported.

If the checksum is valid, the unit will reply to this command with an ACK attention code, where the data field contains

the original command followed by acknowledge from the controller, as described in the appendix. If the checksum is

invalid and the message was not broadcast and RS-485 (for units that support it), the unit will reply to this command

with a NAK attention code, where the data field contains the original command.

Examples:

Command 50% contrast 0x82 0x41 0x38 0x30:

(50% of 0xFF=0x80. In ASCII 80 will be: 0x38 0x30)

0x07

0xFF

0x4D

0x43

0x43

0x04

0x22

0x82

0x41

0x38

0x30

0xD4

Acknowledge 50% Contrast:

0x06

0x03

0x4D

0x43

0x43

0x06

0x1D

0x82

0x41

0x38

0x30

0x38

0x30

0x6C

Unit Type/Model Number “TYP”

This command shall be sent to the unit in order to identify the unit type by its model number / part number. No data

shall be sent with this command.

The unit will reply to this command with an ACK attention code. The DATA field will be set to an ASCII string to

indicate the specified Type/Model Number, e.g: “JH23T01MMD-A1”

Examples:

Command Type/Model Number

0x07

0xFF

0x54

0x59

0x50

0x00

0xFC

Acknowledge Type/Model Number “JH20T03”:

0x06

0xFF

0x54

0x59

0x50

0x07

0x1A

0x4A

0x48

0x32

0x30

0x54

0x30

0x33

0x54

Operational Requirements

The following sections define the operational requirements.

Initial and Default Unit Conditions

After any power cycle, the unit will start-up with the maximum brightness control range available at the local control

and with combined control of the backlight enabled from both the local control (potentiometer) and the remote BRT

command. If no serial messages are received, the unit will stay in this configuration.