Hatteland Display 20 inch - HM 20T07 CMD User Manual

Page 64

Advertising
background image

64

Video Controller Interface Commands

Command Table

IND100103-1

Direct Access

(Hotkeys)

0xa0, “2”,

n |

“r” | “R” |

“?”

Set Hotkey 2 =

value

Reset

Query

“0” – audio mute.

“1” – volume.

“2” – brightness.

“3” – contrast.

“4” – color.

“5” – input source.

“6” – video input.

“7” – zoom

“8” – freeze

“9” – PIP

“A” – Test Pattern

“B” – No function

Set display

orientation

0x8e,

n |

“r” | “R” |

“?”

Set display orientation =

value/increment/decrement

Reset

Query

“0” – normal.

“1” – vertical inverse.

“2” – horizontal inverse.

“3” – inverted.

Auto-calibration

0xc5

Start auto-calibration of gain of

the RGB amplifier.

“0” – fail.

“1” – successful.

Set gamma data for

user defined gamma

curve

0xbf, mm, c, “?”

0xbf, “R” | “r”

0xbf, mm, c, nn

Query gamma data for color c

index mm ( c = 0 for color Red,

c=1 for color Green,

c=2 for color Blue)

Set user gamma curve to linear

Set gamma data for color c

index mm. (If c= 3, then gamma

data for red, green & blue will be

set at the same time.)

“nn” = gamma data

“1”

“nn” = gamma data

Soft Power On/Off

0xc8,

“0” | “1” |

“?”

Soft power

off/on

query

“0” – soft power off.

“1” – soft power on.

Query video input

status

0xc9

Query the status of the primary

& pip status

“nn” = input status

2

nd

digit = primary status:

“0” : invalid

“1” : connected to valid RGB

“2” : connected to valid composite

“3” : connected to valid Svideo

“4” : connected to valid YcbCr

“5” : connected to valid DVI

1

st

digit = PIP input status:

“0” : invalid

“2” : connected to valid composite

“3” : connected to valid Svideo

“4” : connected to valid YcbCr

Query BIOS version 0xcb, “0”

Read BIOS version

“nnnn” = BIOS ver. “nn.nn”

Query PCBA

number

0xcb, “1”

Read PCBA number

“nnnn” = PCBA number

Query average

picture level

0xcc, “0” |

“1” |

“2”

Read APL for red channel

Read APL for green channel

Read APL for blue channel

“nn” = average picture level

Test Pattern

0xcd, “0” |

“1”

Leave test pattern display mode

Display test pattern screen

“0” = normal display

“1” = displaying built in test

pattern

Load the factory

default (Reset

parameter)

0xce

Reset all parameters to default

value

“1” – successful.