Hatteland Display 20 inch - HM 20T07 CMD User Manual

Page 62

Advertising
background image

62

Video Controller Interface Commands

Command Table

IND100103-1

Scalar V Clipping

0xae,

nnn | “+” | “-” |

“r” | “R” |

“?”

Set the vertical clipping size for

non-linear scale mode =

value/increment/decrement

Reset

Query

Scalar vertical clipping

Scalar V Offset

0xaf,

nnn | “+” | “-” |

“r” | “R” |

“?”

Set the vertical offset of the

display window for non-linear

scale mode =

value/increment/decrement

Reset

Query

Scalar vertical offset.

Scalar V stretch

0xb0,

nnn | “+” | “-” |

“r” | “R” |

“?”

Set vertical stretch factor for

non-linear scale mode =

value/increment/decrement

Reset

Query

Scalar vertical stretch.

Select OSD

language

0x95,

n |

“r” | “R” |

“?”

Select language =

English, Danish, Chinese

Reset

Query

“0” – English.

“7” – Danish

“8” – Chinese

Input main select

0x98,

n | “+” | “-” |

“r” | “R” |

“?”

Select input main =

PC or VIDEO or next available

Reset

Query

Main selected.

“0” – PC.

“1” – Composite video.

“2” – S-video.

“3” – Component video.

“4” - DVI

Select menu timeout 0x93,

nn | “+” | “-” |

“r” | “R” |

“?”

Select menu timeout =

value/increment/decrement

Reset

Query

OSD menu timeout value.

“00” – Continuous.

value – Round up to nearest

available step.

if value > max available step, set

it to the max available step.

DPMS Option

0x9f,

“0” | “1” |

“r” | “R” |

“?”

Set power down option =

On/Off

Reset

Query

“0” – Off.

“1” – On.

Display Video

Source Select

0xbc,

“?” |

“0” |

“1”

Query

Name of video source not

displayed.

After switching to a new video

source, the name of the

video source is displayed for 5

seconds.

“0” – disabled.

“1” – enabled.

Auto source select

0x99,

“0” | “1” |

“r” | “R” |

“?”

Set exclusive or priority =

Exclusive/Proirity

Reset

Query

“0” – Exclusive.

“1” – Priority.

“2” – Priority during power up.

GAMMA value

select

0x9d,

n |

“r” | “R”

“?”

Select GAMMA value =

Value

Reset

Query

GAMMA value:

“0” – 1.0, “1” – 1.6

“2” – 2.2, “3” – User Defined

Function

Command

Description

Acknowledge (if enabled)