LEAK TEST MODE

LEAK TEST MODE

This mode is for the technician to investigate odour or

leak complaints and to pinpoint the leak.

4.1 LEAK TEST RANGES

Leak Test mode will have the following ranges available

for normal operation:

•

0 – 2000 ppm CH

4

•

0 – 100% LEL (option to display as gas in air)

•

0 – 100% Vol Gas

•

0 – 2000 ppm CO (if fitted)

4.2 LEAK TEST FEATURES

Leak Test mode will have the following features available:

•

Audible / Visual PPM Ticker (Geiger) Indication -

(Option ON at switch-on)

•

Audible / Visual Gas Alarms

•

Backlight

•

Flashlight

•

Pump - can be toggled ON / OFF and will stop if

flow fault is detected

•

Max Display

•

Autoranging from ppm-LEL-Gas