4-7

LEAK TEST MODE

4.5 DESCRIPTION OF LEAK TEST BUTTON

OPERATION

4.5.1 Ticker (Geiger) ON / OFF
To enable and disable the audible Ticker (Geiger):
(in the PPM range)

•

Press and hold the UP

and DOWN

buttons

simultaneously, as follows:

1. First press and hold - to enable visual only.
2. Second press and hold - to enable both audible

and visual.

When PPM autoranges to LEL, the Ticker (Geiger) audible/

visual continues until an LEL alarm is reached. The Ticker

(Geiger) is then switched off and the LEL alarm will be

activated. If no LEL alarm is set, the Ticker (Geiger) will

remain activated.

4.5.2 Ticker (Geiger) Adjust
To adjust the Ticker (Geiger) threshold:
To increase

•

Press and hold the UP

button.

To decrease

•

Press and hold the DOWN

button.

The threshold setting is displayed briefly beneath the PPM

CH

4

. In the following example, Fig. 4.8, the threshold is

500.