6 leak test ticker (geiger) function, Leak test ticker (geiger) function, 6 leak test ticker (geiger) function -11 – Heath Consultants GT Series User Manual

Page 53

Advertising
background image

4-11

LEAK TEST MODE

When the menu appears on the screen, release

the buttons, otherwise the instrument will proceed

into the switch OFF process and will switch OFF

after a further three (3) seconds.

4.6 LEAK TEST TICKER (GEIGER) FUNCTION

The Ticker (Geiger) function is available on flammable

ppm range. The Ticker (Geiger) range at start-up is

0-1000 PPM.
For any subsequent PPM concentration, the Ticker (Geiger)
audible / visual can be ‘backed off’ using the UP

or

DOWN

buttons.

e.g. 600 PPM Ticker (Geiger) can be ‘backed off’ to enable

tracing to higher concentrations, in which case the Ticker

(Geiger) range becomes 600 to 1600 PPM etc, etc.

Note: The display range remains always as 0 to 2000

PPM.

The Ticker (Geiger) visual is such that the lights illuminate

in pairs according to Fig. 4.9 over any 1000 PPM range as

explained above.