.KVJKWO$CVVGT[%JCTIKPI

.KRQ.K+QP.KHG #FXCPEGF5GVWR

&%*)8QNV Sets the Discharge End Voltage
The Hitec H4 Multi Charger provides a minimum discharge voltage for your battery. This function is helpful in safely discharging your Lithium chemistry batteries.
Before changing this setting, refer to the data from the battery's manufacturer. The factory set up is the ‘Default’ value which is: LiPo = 3.7v, LiIon =3.7v,
and LiFe = 3.3v. You can manually set it up by 0.01v increments.

&%*)'PF Set the Discharge or Charge End Current (Auto or 60~500mA)
This sets the ſnal charge/discharge current at the end of the process. In ‘Auto’ mode, the process will terminate when the charging current goes to 1/10th of its initial
value. Otherwise, the charge current will be decreased until the designated value has been reached. The end current should be less than the initial charge current.

%JGEM6KOG Set Cycle Interval Time (In Cycle Mode)
In ‘Cycle Mode,’ the batteries' internal temperatures are increased when charged and discharged and need time to cool down. You can manually set up cool down
in one minute increments with a set up range from 5 - 250 minutes. The default check time is 10 minutes.

5CHGV[6GOR Sets the Safety Temperature when using the optional temperature probe
You can monitor battery temperature during the charge/discharge process via the Temp sensor (sold separately). The default is set to 50°C (122°F) but can be
adjusted between 20°C to 80°C (68° to 176°F).

This function will be activated when the temp sensor is connected to the H4 charger.

5CHGV[6KOGT Sets the maximum time the H4 will charge or discharge a battery.
When you start to charge or discharge the battery, the H4’s internal clock will start counting total processing time. By having a set safety time, the function will help
prevent battery damage from over charging or discharging. The default is set at 2 hours and can be set from 10 to 1,380 minutes.

Advanced Charge/Discharge Setup Page 1

Advanced Charge/Discharge Setup Page 2

.KVJKWO$CVVGT[%JCTIKPI .KRQ.K+QP.KHG #FXCPEGF5GVWR

%*)8QNVSets the Charge End Voltage
The Hitec H4 Multi Charger provides a maximum charge voltage for your battery. This function is helpful in safely charging your Lithium chemistry batteries. Before
changing this setting, refer to the data from the battery's manufacturer. The factory set up is the ‘Default’ value which is: LiPo = 4.2v, LiIon =4.1v, LiFe = 3.6v. You
can manually set it up by 0.01v increments.