&GNVC2GCM The automatic charge termination program utilizes Delta Peak voltage detection. When the battery’s voltage exceeds the threshold, the charge process
is terminated automatically.



&GHCWNVDefault refers to the basic sensitivities of Delta Peak. If you are not familiar with this function, you should use the default value.



&GNKECVG Some batteries need to be charged with a sensitive Delta Peak value.



&KUCDNGIf you don’t want to use Delta Peak detecting, please select ‘Disable.’



/CPWCN#FLWUVOGPVThe Delta Peak value adjustable range is 5mV/Cell to 20mV/C. We recommend you use 10mV/Cell on a NiMH battery and

15mV/Cell on a NiCd battery.

&2GCM&GNC[ Sets the Delay for the Delta Peak Function
The Delta Peak function will not initiate once the charge process begins, until you reach the set delay time. Since some batteries have high internal resistance,
the Delta Peak works before it is fully charged. If your battery is old and is fully discharged enough, we recommend you use this function to stabilize the voltage.
However, if you have no idea if your battery is fully discharged or not, do not use this function on your battery. The function can be turned OFF or adjusted between
1 and 15 minutes.

6TM%WTT Sets the Trickle Current Rate
When the charge process ends, current is fed to the battery to compensate for the natural discharge. Use this feature to set the trickle current rate. The function
can be turned OFF or adjusted between 50 to 300mA.

&%*)8QNV Sets the Minimum Discharge Voltage
Use this function to prevent the decline of your battery’s life and performance. When used, over discharging will not occur. You should set the discharge voltage
according to the battery manufacturer’s recommendations. The default setting is 0.9V/Cell.

&GNC[6KOGSets Charge/Discharge Cycle Delay Time
A battery's internal temperature increases during the charge or discharge process and needs time to cool down in ‘Cycle Mode.’ The adjustable range for this
interval is 0 to 60 minutes. This delay time function is only activated when using ‘Cycle Mode.’

5CHGV[6'/2 Sets the Safety Temperature when using the optional temperature probe
You can monitor battery temperature during the charge/discharge process via the Temp sensor (sold separately). The default is set to 50°C (122°F) but can be
adjusted between 20°C to 80°C (68° to 176°F).

0K%FCPF0K/*$CVVGT[#FXCPEGF5GVWR

The previous section referred to the quick start method of charging NiCd and NiMH batteries. In this section, you will ſnd information about ſne tuning your setup
to get the most out your battery. Be sure to follow the battery manufacturer’s recommendations when setting up these advanced features. To get to the advanced
setup screen, use the (V) to scroll down to the following screens.