.GCF#EKF 2D $CVVGT[%JCTIKPI2TQITCO

This program is only suitable for charging a lead acid (Pb) type battery with a nominal voltage range of 2 to 20 volts. Lead acid (Pb) batteries can only deliver
currents lower in comparison to their capacity. The same restriction applies to the charging process. The optimal charge current for lead acid (Pb) batteries is
1/10th of its rated capacity. (i.e. battery capacity is 4,000 mAh, charging current is 400 mAh). You cannot fast charge lead acid (Pb) batteries. You should refer to
the battery's detailed specs from the battery manufacturer. 6JGHQNNQYKPIURGEKſECVKQPURGTVCKPVQEJCTIKPICPFFKUEJCTIKPINGCFCEKF 2D DCVVGTKGU

Please select Pb from the battery type prompt. If the wrong selection is made,
you will damage the H4 and the battery. Press the (V) button to continue.

Select the exact numbers cells in your battery. Choosing the incorrect number
of cells will damage the H4 and your battery. Press the (V) button to continue.

Highlight the Charge or Discharge Amperage depending on what action
you want to process. Press and hold the Start button until the Normal/Pulse
Charge screen appears

Please set up the exact battery capacity in mAh. Since the battery capacity
is interlocked with the charging Amps (A), the charging Amps are based on
a 1C charge rate When the battery reaches the target capacity, the charge
process will terminate automatically. Press the (V) button to continue.

Choose either Normal or Pulse Charge and press enter to begin the Charge
process.

Once started the charging progress screen will appear.

0QOKPCN8QNVCIG.GXGN 2.0V per cell
/CZKOWO%JCTIG8QNVCIG 2.46V per cell

#NNQYCDNG%JCTIG%WTTGPV 0.4C or less
&KUEJCTIG8QNVCIG%WV1HH.GXGN 1.75V or higher per cell