Section 2.2.6 Access Control Operation


To gain access control the user must use one of two means or a combination of these two means.
These means are the RUN/PROG key or the user password system.

Section 2.2.6.1

RUN/PROG Key Switch Operation


The RUN/PROG key switch is located on the lower right side of the operator terminal. This is a
two-position switch. The key is removable in the RUN position only. If the RUN/PROG key
switch is being used as a means to access the restricted items, the switch must be turned to the
PROG position. When the RUN/PROG key switch is switched to the PROG position, the press
will Top Stop and stroking will be prohibited until the switch is returned to the RUN position.


When operating in the Key Only mode the key switch is the only means available to access the
restricted items. All restricted items are accessible when the RUN/PROG key switch is switched
to the PROG position.

When operating in the “Key or Password” mode, the key switch is one of the means available to
access the restricted items. All restricted items are accessible when the RUN/PROG key switch
is switched to the PROG position.

When operating in the “Key and Password” mode, the key switch and password must be used to
access the restricted items. In this mode, the user will be granted access only to the restricted
items that have been assigned to him.

Section 2.2.6.2

Password System Operation


Figure 2.2 displays a typical password entry sequence. This example shows the steps necessary
to change a slide adjust setpoint. This is typical for password entry for all restricted items.