LINK Systems Omni II Automatic Setups Module User Manual

Page 33

Advertising
background image

October 16, 2008

Manual Version 1.1

4-5

a)

Go to the Auto Sets screen. This screen is reached by pressing the AUTO SETS
softkey in the Main Menu or Press Control screen.

b)

With the RUN/PROG key switch in the PROG position, press the CONFIGURE
softkey and enter the configuration code. Note that the code is provided separately
from this manual for administrative control.


The screen shown in Figure 4.3 will appear.

Stroke

Mode

Inch

Drive

Speed

Stroke

Speed

SPM

SPM

0
0

Order

Counter

PC STATUS

Counter OFF

EXIT

0

0

Program/Run Switch

TOP

Auto-Setup
Config

Auto-Setup Module 1

Slide Slot 1:
Slide Slot 2:

Air Slot 1:
Air Slot 2:
Air Slot 3:
Air Slot 4:

Air Slot 5:

CHANGE
SETTING

CONFIGURE
SYSTEM

NEXT
PAGE

Slide 1
Not Used

Counter-Balance 1
Not Used
Not Used
Not Used

Not Used

Figure 4-3 Auto-Setups Module Configuration Screen

Auto-Setup Module 1 configuration options are displayed in Figure 4-3. If more than one
automatic setup module is present, press the NEXT PAGE softkey to display the next module.
All connected modules must be configured.

Section 4.2.1 Configuring Air Systems


The OmniLink II Press Automation Control Automatic Setup module can control counterbalance
pressure, cushion pressure, and hydraulic overload control pressure. Counterbalances and
cushions are conceptually very similar and use essentially the same control techniques.
Hydraulic overloads are somewhat different but are usually systems controlled by air pressure
(there are some non-air controlled hydraulic overloads but the auto-setup board does not support
them) {Hydraulic Overload trip point control is currently unavailable}.

To start the configuration process for an installed air system, the hardware slot must be told the
type of device that it is to control. Slots AS1 to AS4 can control either counterbalances or

Advertising