LINK Systems Omni II Automatic Setups Module User Manual

Page 18

Advertising
background image

October 16, 2008

Manual Version 1.1

3-4

1. Input Power
2. High Speed Serial Bus Cable
3. Set High Speed Serial Bus Termination Switch


Wiring of the slide adjust systems and air adjust systems will be described in the specific
sections which describe their use and their connections.

L1

GND

NEU

GND

AUTO SETUP

S

A
1

2

S

S

2

S

A

S

A
4

A

S

3

1

S

S

Figure 3-4 Primary Wiring and High Speed Bus Termination

Section 3.1.4.1

Wiring Input Power


Connection of AC input power is made to the 3 pin terminal block on the bottom of the module.
The pinout is provided on Figure 3.4. The 3 pin plug supplied for connection of input power is a
dual connector plug. This dual connector plug allows for input power to be strung from module
to module if additional OmniLink II Press Automation Control modules are to be wired from the
same power source.

Section 3.1.4.2

Wiring High Speed Serial Bus Cable


The high speed serial bus cable is wired to the 4 pin terminal block that is just above the power
connector terminal block. The pinout is provided on Figure 3.4. The cable that is supplied by
Link Systems for the high-speed serial bus that interconnects the various components of the
OmniLink II Press Automation Control must be used. This cable must run from device to device
without being spliced.