LINK Systems Omni II Automatic Setups Module User Manual

Page 12

Advertising
background image

October 16, 2008

Manual Version 1.1

2-6

SPM

SPM

0
0

Order

Counter

PC STATUS

READY TO STROKE

Counter OFF

Auto
Setup

CHANGE
NUMBER

SPM

SPM

0
0

Order

Counter

PC STATUS

READY TO STROKE

Counter OFF

Auto
Setup

SUPPLY
ACCESS
CODE

SPM

SPM

0
0

Order

Counter

PC STATUS

READY TO STROKE

Counter OFF

Auto
Setup

CHANGE
NUMBER

SPM

SPM

0
0

Order

Counter

PC STATUS

READY TO STROKE

Counter OFF

Auto
Setup

SELECT

STEP A: SELECTING PARAMETER TO BE CHANGED

STEP B: SELECTING USER NAME

STEP C: ENTERING USER PASSWORD

STEP D: CHANGING PARAMETER

PRESS SUPPLY
ACCESS CODE KEY

Slide Adjust #1 (ON)

Setpoint:

Actual

Shutheight

Fault:

Status:

None
In Position

20.000

20.000

in

in

Slide Adjust #1 (ON)

Setpoint:

Actual

Shutheight

Fault:

Status:

None
In Position

20000

20.000

in

in

SELECT A USER NAME

USER NUMBER ONE
USER NUMBER TWO
USER NUMBER FIVE

Setpoint:

Actual

Shutheight

Fault:

Status:

None
In Position

20.000

20.000

in

in

USER NUMBER ONE CODE _______

Slide Adjust #1 (ON)

Setpoint:

Actual

Shutheight

Fault:

Status:

None
In Position

20.000

in

in

Slide Adjust #1 (ON)

__.___

Figure 2-2 Example Password Entry

Step A:

Select the restricted item. In the example shown in Figure 2.2 the restricted item is
Slide Adjust #1 setpoint. Once the parameter is selected then Softkey # 1, the upper
vertical softkey (Softkey # 1 is highlighted in Figure 2.2), will display the legend
“SELECT”.


Step B:

A list of users that have access to this restricted item will appear. In the example
shown in Figure 2.2 only User Number One, User Number Two, and User Number
Five have access to this restricted parameter. The system may have several more
users, but the three users listed on the screen are the only users that have access to
change an Auto Setup Setting. The user must use the arrow keys to position the
cursor on his user name. After placing the cursor on the correct name, the user must
press the SELECT softkey. The SELECT softkey must be pressed even if there is
only one user name displayed.


Step C:

The display will show the selected user name and request the user password. The
user must enter the correct password and then press the ENT key.


Step D:

Upon entry of the correct password, the user will be allowed access to the restricted
item. In the example shown in Figure 2.2, the user will have access to change the
Slide Adjust #1 setpoint.

Advertising