LINK Systems Omni II Automatic Setups Module User Manual

Page 36

Advertising
background image

October 16, 2008

Manual Version 1.1

4-8

setting is 2.


Fault Time

If the pressure in the counterbalance goes out of tolerance due to a leak or
any other reason, a countdown starts. The module will try to bring the
pressure back into tolerance before the countdown expires. If it cannot
correct the pressure, the press will be stopped. The fault time is the
countdown in seconds. Suggested value is 20 seconds.


Transducer Full Scale This value depends on the full scale rating of the pressure transducer

being used. All pressure transducers must have a 4 to 20 milliamp output.
The “Transducer Full Scale” is the pressure that the transducer is reading
when its output is 20 milliamps. It is suggested that the full scale rating of
the transducer be at least two times the maximum air pressure rating of the
counterbalance. Since counterbalance air pressure is not constant and
increases as the slide approaches bottom dead center, a transducer rating
of at least two times maximum air pressure is suggested.

Section 4.2.1.2

Configuring Cushion Systems


The cushion configuration screen is shown in Figure 4.5.

Stroke

Mode

Inch

Drive

Speed

Stroke

Speed

SPM

SPM

0
0

Order

Counter

PC STATUS

Counter OFF

EXIT

0

0

Program/Run Switch

TOP

Auto-Setup
Config

Cushion 1 Configuration

Module:

Air Slot:

Mode:

Display Force As:

Max. Cushion Force:

Min. Cushion Force:

Max. Pressure:

Min. Pressure:

Tolerance:

Fault Time:

Transducer Full Scale

Parameter Help

CHANGE
SETTING

1
2

ON

lbs
2500 lbs

0 lbs

50 psi
15 psi

2 psi

20 seconds

200 psi

System not used.
System will go to setpoint and job recalls
will change the setpoint.
System will go to setpoint but job recalls
will not change the setpoint.

OFF

ON

MANUAL

-
-

-

Figure 4-5 Cushion Configuration


There are several parameters that must be configured in this screen. The editing cursor indicates
which parameter is currently selected. Softkey 1 (the uppermost vertical softkey) will change its
description based on the parameter and, when pressed, allows the currently selected parameter to

Advertising