tolerance limits. To configure a particular air system, move the cursor to that system and press
the CONFIGURE SYSTEM softkey.

The slide adjust configuration screen is shown in Figure 4.6.

Stroke

Mode

Inch

Drive

Speed

Stroke

Speed

SPM

SPM

0
0

Order

Counter

PC STATUS

Counter OFF

EXIT

0

0

Program/Run Switch

TOP

Auto-Setup
Config

Slide 1 Configuration

Module:

Slide Slot:

Mode:

Shut Height Units

Upper Limit:

Lower Limit:

Tolerance:

Pulse Distance:

Pulse Time:

Resolver Turns:

Parameter Help

CHANGE
SETTING

1
1

ON

in

20.000 in
14.000 in

.004 in
.010 in

30 mses

100

System ignores setpoint but jog softkeys work.
System uses setpoint and job recalls will
change the setpoint.
System uses setpoint but job recalls will
NOT change the setpoint.

OFF

ON

MANUAL

-
-

-

CALIBRATE

Figure 4-6 Slide Configuration Screen

There are several parameters that must be configured in this screen. The editing cursor indicates
which parameter is currently selected. Softkey 1 (the uppermost vertical softkey) will change its
description based on the parameter and, when pressed, allows the currently selected parameter to
be changed. The up and down arrow keys move the editing cursor from one parameter to
another. See Appendix A for examples of setting up each kind of system. The features of this
screen are:

Help The

“Help”

box

at

the

bottom

of the screen changes depending on the

parameter that the editing cursor is currently on. It gives a short version of
how the parameter is used.


Module

Corresponds to the physical Automatic Slide Adjust module number to
which the slide adjust module is currently connected. This is a display
parameter only and cannot be changed.


Slide Slot

Corresponds to the physical slot number, SS1 or SS2, to which the slide
adjust module is currently plugged into. This is a display parameter only
and cannot be changed.