Altera Remote Update IP Core User Manual

Page 12

Advertising
background image

Name

Port

Required?

Description

write_param

Input

No

Write signal for parameter specified in

param[]

and

with value specified in

data_in[]

.

Signal indicating parameter specified with

param[]

should be written into remote update block with the

value specified in

data_in[]

. The number of bits

read from

data_in[]

depends on the parameter type.

The signal is sampled at the rising clock edge. The

signal should be asserted for only one clock cycle to

prevent the parameter from being rewritten on a

subsequent clock cycle. The busy signal is activated as

soon as

write_param

is read as being active. While

the parameter is being written, the busy signal

remains asserted, and input to

data_ in[]

is ignored.

When the busy signal is deactivated, another

parameter can be written. This signal is only valid in

Factory configuration mode because parameters

cannot be written in Application configuration mode.
The signal cannot be used in Local update mode.

param[]

Input

No

Bus that specifies which parameter need to be read or

updated.
A 3-bit bus that selects the parameter to be read or

updated. If left unconnected, the default value for this

port is 000.

data_in[]

Input

No

Data input for writing parameter data into the remote

update block. Input bus for parameter data.
For some parameters, not all bits are used. In this

case, the lower-order bits are used (for example,

status values use bits

[4:0]

).

If left unconnected, this bus defaults to 0. The port is

ignored if the current configuration is the Application

configuration.
A 32-bit bus width(4-bytes addressing configuration

device, for example EPCQ-L256) in the Quartus II

software version 14.0 or later.

reconfig

Input

Yes

Signal indicating that reconfiguration of the part

should begin using the current parameter settings. A

value of 1 indicates reconfiguration should begin.

This signal is ignored while busy is asserted to ensure

all parameters are completely written before reconfi‐

guration begins.

12

Ports

UG-31005

2015.04.07

Altera Corporation

Altera Remote Update IP Core User Guide

Send Feedback