Altera Remote Update IP Core User Manual

Page 33

Advertising
background image

Name

Port

Required

?

Description

asmi_dataout

Input

No

Input from the

altasmi_parallel

component.

Available when the

check_app_pof

parameter is

set to

true

.

The Altera Remote Update IP core presents the

address information on this pin before initiating

the read operation on the ALTASMI_

PARALLEL IP core.

pof_error

Output

No

Detects and invalid application configuration

image.
Available when the

check_app_pof

parameter is

set to TRUE.
A logic high on this pin indicates that the Altera

Remote Update IP core detects an invalid

application configuration image. If asserted high,

you must take corrective action by reloading a

new application configuration image or

specifying a different address location in the

EPCS or EPCQ that contains a valid application

configuration image. Wire this pin based on your

system requirement.

asmi_addr

Output

No

Address signal to

altasmi_parallel

component.
Available when the

check_app_pof

parameter is

set to TRUE. The Altera Remote Update IP core

presents the address information on this pin

before initiating the read operation on the

ALTASMI_PARALLEL IP core.
Wire this pin to the

asmi_addr

input port of the

ALTASMI_PARALLEL IP core.

asmi_read

Output

No

Read signal to

altasmi_parallel

component.

Available when the

check_app_pof

parameter is

set to TRUE. A logic high on this pin initiates the

read operation on the ALTASMI_PARALLEL IP

core.
Wire this pin to the

asmi_read

input port of the

ALTASMI_PARALLEL IP core.

UG-31005

2015.04.07

Ports

33

Altera Remote Update IP Core User Guide

Altera Corporation

Send Feedback