Name

Port

Required

?

Description

write_param

Input

No

Write signal for parameter specified in

param[]

and with value specified in

data_in[]

.

Signal indicating parameter specified with

param[]

should be written into remote update

block with the value specified in

data_in[]

. The

number of bits read from

data_in[]

depends on

the parameter type.
The signal is sampled at the rising clock edge.

The signal should be asserted for only one clock

cycle to prevent the parameter from being

rewritten on a subsequent clock cycle. The busy

signal is activated as soon as

write_param

is read

as being active. While the parameter is being

written, the busy signal remains asserted, and

input to

data_in[]

is ignored. When the busy

signal is deactivated, another parameter can be

written. This signal is only valid in Factory

configuration mode because parameters cannot

be written in Application configuration mode.
The signal cannot be used in local update mode.

param[]

Input

No

Bus that specifies which parameter need to be

read or updated.
A 3-bit bus that selects the parameter to be read

or updated. If left unconnected, the default value

for this port is 000.
For more information, refer to

Parameters

on

page 34.