read_

para

m

write

_

para

m

read_source param

Remote Update Operation

data_out

width

(bits)

MSM Mode

0

1

[00]

[011] Write the watchdog enable bit.

All parameters can be written in factory

mode only.

1

Factory

0

1

[00]

[100] Write application boot address.

All parameters can be written in factory

mode only.

22

Factory

0

1

[00]

[110] Write to force the internal oscillator as

startup state machine clock. All parameters

can be written in factory mode only.

1

Factory

1

0

[11]

[001] Read the early

confdone

check bits

1

Factory

1

0

[11]

[010] Read watchdog time-out value

12

Factory

1

0

[11]

[011] Read watchdog enable bit

1

Factory

1

0

[11]

[100] Read boot address

22

Factory

1

0

[11]

[110] Read to check whether the internal oscillator

is set as startup state machine clock

1

Factory

read_source

The following table lists the details for

read_source

.

read_source

specifies whether a parameter value is

read from the current or a previous state. When you trigger the read operation, all contents in status

register or input register latched to the

data_out

node in the Altera Remote Update IP core.

Table 14: read_source

read_source

Description

00

Current state contents in status register

01

Previous state register 1 contents in status register

10

Previous state register 2 contents in status register

11

Current contents is in input register

State Register

The previous state register 1 reflects the current application configuration and the previous state register 2

reflects the previous application configuration.

UG-31005

2015.04.07

Remote Update Operation

37