Altera Remote Update IP Core User Manual

Page 36

Advertising
background image

read_

para

m

write

_

para

m

read_source param

Remote Update Operation

data_out

width

(bits)

MSM Mode

1

0

[00]

[000] Master State Machine Current State Mode

(Read Only)
• 00—Factory mode

• 01—Application mode

• 11—Application mode with Master State

Machine User Watchdog Timer Enabled

2

Factory or

Application

1

0

[00]

[100] Read factory boot address

24

Factory

1

0

[01]

[100] Read Past Status 1 boot address.

For more information, refer to

Figure 11

.

24

Factory

1

0

[01]

[111] Read Past Status 1 reconfiguration trigger

condition source.
For more information, refer to

Figure 11

.

5

Factory

1

0

[10]

[100] Read Past Status 2 boot address.

For more information, refer to

Figure 11

.

24

Factory

1

0

[10]

[111] Read Past Status 2 reconfiguration trigger

condition source
For more information, refer to

Figure 11

.

5

Factory

1

0

[01]

[010] Read current application mode watchdog

value

29

Application

1

0

[01]

[011] Read current application mode watchdog

enable

1

Application

1

0

[10]

[100] Read current application mode boot address

24

Application

0

1

[00]

[001] Write the early

confdone

check bit.

All parameters can be written in factory

mode only.

1

Factory

0

1

[00]

[010] Write the watchdog time-out value.

All parameters can be written in factory

mode only.

12

Factory

36

Remote Update Operation

UG-31005

2015.04.07

Altera Corporation

Altera Remote Update IP Core User Guide

Send Feedback