Remote system configuration mode – Altera Remote Update IP Core User Manual

Page 15

Advertising
background image

Bit

Parameter

Width

Comments

010

Watchdog Timeout Value

12

011

Watchdog Enable

1

100

Page Select

32

For the Quartus II software version 14.0 and onwards:
• Width of 32 when reading and writing the start

address.

• For active serial devices using 32-bit addressing,

such as EPCQL-256,

PGM[31..2]

corresponds to

the upper 30 bits of the 32-bits start address.

PGM[1..0]

is read as

2'b0

.

101

Configuration Mode (AnF)

1

In local update mode, this parameter can only be read.

This parameter is set to 1 in application page and is set

to 0 in factory page. In remote update mode, this

parameter can be read and written.
Before loading the application page in remote update

mode, Altera recommends that you set this parameter

to 1. The content of the control register cannot be read

properly if you fail to do so.

110

Illegal Value

111

Illegal Value

Arria II, Arria V, Cyclone V, Stratix IV, and Stratix V Devices

This section covers the remote system configuration modes, components, parameter, ports, and

parameter settings for Arria II, Arria V, Cyclone

®

V, Stratix

®

IV, and Stratix V devices.

Remote System Configuration Mode

Arria II, Arria V, Cyclone V, Stratix IV, and Stratix V devices support remote configuration mode only.

UG-31005

2015.04.07

Arria II, Arria V, Cyclone V, Stratix IV, and Stratix V Devices

15

Altera Remote Update IP Core User Guide

Altera Corporation

Send Feedback