Factory default switch settings, Factory default switch settings –2, Figure 4–1 – Altera Signal Integrity Development Kit, Stratix V GX Edition User Manual

Page 14: Shows the, Switch 1 has the following options, Open = vccrt_gxb select at 0.90 v, Switch 2 has the following options, Open = vcca_gxb select at 2.5 v, Close = vcca_gxb select at 3.0 v close

Advertising
background image

4–2

Chapter 4: Development Board Setup

Factory Default Switch Settings

Transceiver Signal Integrity Development Kit

July 2012

Altera Corporation

Stratix V GX Edition User Guide

Factory Default Switch Settings

This section shows the factory switch settings for the Stratix V GX transceiver signal
integrity development board.

Figure 4–1

shows the switch locations and the default position of each switch on the

top side of the board.

To restore the switches to their factory default settings, perform the following steps:

1. Set the DIP switch bank (SW2) to match

Table 4–1

and

Figure 4–1

.

Figure 4–1. Switch Locations and Default Settings on the Board Top

SW4

1 2 3 4 5 6 7 8

S7

1 2 3 4 5 6

MSEL0

MSEL1

MSEL2

MSEL3

MSEL4

MAX BYPASS

1

SW6

1 2 3 4

0

1

0

OSC

SMA

S5_UNLOCK

DPI6

DPI0

SW3

1 2 3 4

1 2 3 4

SW7

ENABLE

DISABLE

SW3-1 VCC
SW3-2 VCCRT_GXB
SW3-3 VCCA_GXB
SW3-4 1p5V
SW7-1 2p5V
SW7-2 VCCR_GTB
SW7-3 VCCT_GTB
SW7-4 VCCL_GTB

SW5

1 2 3 4

ON

S0 S1 SS0 SS1

S1 S0 CLK

0 0 25MHz

0 1 100MHz

1 0 125MHz

1 1 200MHz

SW2

1 2 3 4

ON

open

close

SW2-1 OPEN=0.90V
SW2-1 CLOSED=1.0V
SW2-2 OPEN=2.5V
SW2-2 CLOSED=3.0V
SW2-3 = No Function
SW2-4 = No Function

J28

(PGMSEL)

PGMSEL
JMP1-2=USER

JMP2-3=FACTORY

3

1

ON

ON

1

0

J26

AUTO ON

3

1

(Fan select)

(User defined)

0 = Closed
1 = Open

Table 4–1. SW2 Dip Switch Settings (Part 1 of 2)

Switch

Board

Label

Function

Default

Position

1

SW2-1

(1)

Switch 1 has the following options:

Open = VCCRT_GXB select at 0.90 V

Close = VCCRT_GXB select at 1.0 V

Close

2

SW2-2

(1)

Switch 2 has the following options:

Open = VCCA_GXB select at 2.5 V

Close = VCCA_GXB select at 3.0 V

Close