The Molex Tab

The Molex tab allows you to run an x4 backplane loopback test through the Molex
connector.

Figure 6–8

shows the Molex tab.

1

No loopback board is provided. A loopback backplane can be purchased from Molex.

The following sections describe the controls on the Molex tab.

Status

The Status control displays the following status information during the loopback test:

PLL lock

—Shows the PLL locked or unlocked state.

Channel lock

—Shows the channel locked or unlocked state. When locked, all

lanes are word aligned and channel bonded.

Pattern sync

—Shows the pattern synced or not synced state. The pattern is

considered synced when the start of the data sequence is detected.