No loopback is provided. A loopback backplane can be purchased from Amphenol.

The following sections describe the controls on the Amphenol tab.

Status

The Status control displays the following status information during the loopback test:

PLL lock

—Shows the PLL locked or unlocked state.

Channel lock

—Shows the channel locked or unlocked state. When locked, all

lanes are word aligned and channel bonded.

Pattern sync

—Shows the pattern synced or not synced state. The pattern is

considered synced when the start of the data sequence is detected.

Port

The Port control allows you to specify the type of test to run on the Amphenol port.
The following Amphenol port tests are available:

Amphenol x4 Transceivers

aggressor 1 to 6

—If available, turning on an aggressor box will turn on the

adjacent aggressor channels adding switching noise to the victim channel to be
used for backplane analysis.

PMA Setting

The PMA Setting button

allows you to make changes to the PMA parameters that

affect the active transceiver interface. The following settings are available for analysis:

Serial Loopback

—Routes signals between the receiver to the transmitter.

VOD

—Specifies the voltage output differential of the transmitter buffer.

Pre-emphasis tap

Pre

—Specifies the amount of pre-emphasis on the pre-tap of the transmitter

buffer.

First post

—Specifies the amount of pre-emphasis on the first post tap of the

transmitter buffer.

Second post

—Specifies the amount of pre-emphasis on the second post tap of

the transmitter buffer.

Equalizer

—Specifies the setting for the receiver equalizer.

DC gain

—Specifies the DC portion of the receiver equalizer.

Data Type

The Data type control specifies the type of data contained in the transactions. Select
the following available data types for analysis:

PRBS7

—pseudo-random 7-bit sequences (default)

PRBS15

—pseudo-random 15-bit sequences

PRBS23

—pseudo-random 23-bit sequences