Chapter 6: Board Test System

6–13

Using the Board Test System

July 2012

Altera Corporation

Transceiver Signal Integrity Development Kit

Stratix V GX Edition User Guide

SFP+

XFP

PMA Setting

The PMA Setting button

allows you to make changes to the PMA parameters that

affect the active transceiver interface. The following settings are available for analysis:

Serial Loopback

—Routes signals between the receiver to the transmitter.

VOD

—Specifies the voltage output differential of the transmitter buffer.

Pre-emphasis tap

Pre

—Specifies the amount of pre-emphasis on the pre-tap of the transmitter

buffer.

First post

—Specifies the amount of pre-emphasis on the first post tap of the

transmitter buffer.

Second post

—Specifies the amount of pre-emphasis on the second post tap of

the transmitter buffer.

Equalizer

—Specifies the setting for the receiver equalizer.

DC gain

—Specifies the DC portion of the receiver equalizer.

Data Type

The Data type control specifies the type of data contained in the transactions. Select
the following available data types for analysis:

PRBS7

—pseudo-random 7-bit sequences (default)

PRBS15

—pseudo-random 15-bit sequences

PRBS23

—pseudo-random 23-bit sequences

PRBS31

—pseudo-random 31-bit sequences

HF1

—highest frequency divide-by-2 data pattern "10101010"

HF2

—next highest frequency divide-by-6 data pattern "111000111000"

HF3

—second lowest frequency divide-by-22 data pattern

LF

—lowest frequency divide by 33 data pattern

1

Settings HF1, HF2, HF3, LF are for transmit observation only and are not
used in the receiver data detection circuitry.

Error Control

This control displays data errors detected during analysis and allows you to insert
errors:

Detected errors

—Displays the number of data errors detected in the received bit

stream.

Inserted errors

—Displays the number of errors inserted into the transmit data

stream.