Configuration & reset buttons, Sw8 - cpu reset – Altera Nios Development Board User Manual

Page 34

Advertising
background image

1–26

Altera

Corporation

Nios Development Board Reference Manual, Cyclone Edition

December 2004

Configuration Controller Device (EPM7128AE)

Figure 1–18. LED1 – LED4

Configuration & Reset Buttons

The Nios development board uses dedicated switches SW8, SW9 and
SW10 for the following fixed functions:

SW8 – CPU Reset

When SW8 is pressed, a logic-0 is driven onto the Cyclone devices'
DEV_CLRn pin (and user I/O C_4). The result of pressing SW8 depends
on how the Cyclone device is currently configured.

The pre-loaded Nios II reference design treats SW8 as a CPU-reset pin
(see

Figure 1–19

). The Nios II reference design will reset and start

executing code from its reset address when SW8 is pressed.

Table 1–8. Configuration Status LED Indicators

LED LED

Name

Color

Description

LED3

Loading

Green

This LED blinks while the configuration-controller is actively transferring
data from flash memory into the Cyclone FPGA.

LED4

Error

Red

If the red Error LED is on, then configuration was NOT transferred from
flash memory into the Cyclone device. This can happen if, for example, the
flash memory contains neither a valid user or safe configuration.

LED1

User

Green

If the Cyclone device was successfully configured with data from the
EPCS4, LED1 will blink slowly. If the Cyclone device was successfully
loaded with the user configuration from flash memory, LED1 will remain on
continuously.

LED2

Force Safe Amber

This LED turns on when the safe configuration is being transferred from
flash memory and stays illuminated if the safe configuration was
successfully loaded into the Cyclone device.