HB3256-03

Page 11

OPTIONAL SENSORS

.

Wind Speed

Description
This sensitive anemometer is based upon the three cup rotor design. The instrument is robust
and easy to use, with overall design determined by the extensive use of the Royal College of
Aeronautics (CIT) wind tunnel facilities.
The instrument has been designed and tested to meet the recommendations adopted by the
European Commission CIMO (WMO N272 Brussels 11-22 September 89).
The instrument is constructed using Aluminium alloy, which is then anodised. This results in a
durable all weather construction.

Specification
Transducer

Optical interrupter

Maximum design wind speed

75 metres/second

Starting velocity

Typically 0.4 metres/second

Distance constant

Typically 5.3

Resolution

7.2 cms

Non-Linearity

† 0.6 % (from 3 to 40 metres/second)

Accuracy

† 1% above 3 metres/second

Calibration

13.8 Hz/metre/second

Pulses per rev

20

Operating temperature range

-20

°C to + 70°C

Storage temperature range

-50

°C to + 70°C

Supply voltage

7-20 volts d.c.

Current consumption

Typically 15mA at 12 volts

Output calibration

0 to 5 volt pulses.

Part no.

120800B-03

Advertising