Wind Direction

Description
This sensitive wind vane has been designed and tested to meet the recommendations adopted by
the European Commission CIMO (WMO N272 Brussels 11 - 22 September 1989).
The instrument is constructed using aluminium alloy, which is then anodised. This results in a
durable all weather construction.

Specification
Transducer

Continuous rotation wirewound
potentiometer

Maximum design wind speed

75 metres/second

Aligning threshhold

1.2 metres/second @ 10° offset

Distance constant

Typically 2.3

Undamped natural wavelength

6.2 metres

Damping ratio

0.35 to 0.45

Repeatability

0.5% f.s.d.

Time constant

0.35 second

Electrical angle

0 - 355° (north between 355° and 0°)

Operating temperature range

-20°C to +70°C

Storage temperature range

-50°C to +70°C

Supply voltage

7 to 20 volts d.c.

Current consumption

Typically 2 to 3mA at 12 volts

Output calibration

0 to 1.8 volts d.c. for 0 - 355° rotation.
Deadband = 0 volts output

Part no.

120804B-04