Operation guide – Pinnacle Systems STTS User Manual
Page 12
6
OPERATION GUIDE
At power-up the control will go though a test and then, if manual reset option is enabled you must reset
the zone. If automatic reset is enabled, the unit will activate each zone that passes the test and nothing
is found on the mat(s).
WHEN YOU STEP ON THE MAT:
The corresponding yellow mat input LED will turn on and, at the same time, the green zone LED will turn
off and the red zone LED will turn on. All three relays related to this zone will de-energize and open up
the N.O. outputs.
WHEN YOU STEP OFF THE MAT:
The corresponding condition of the LED's described above will reverse. All three relays related to this
zone will energize and close the N.O. outputs
GETTING FAULT CODES:
The yellow mat input LED corresponding to the mat fault will flash to indicate which mat input circuit or
mat is faulting. All available zones will shut down and de-energize all relays. When 1 zone has a fault, all
zones shut down.
Problem:
NO FAULT CODES DISPLAYED, BUT THE ZONE WILL NOT CLEAR
(No Green LED, but a Yellow LED is lit)
Cause:
1) Manual reset button needs to be pushed.
2) Something is on the mat, or the trim around the mat is too tight.
3) Mat failure (short in the wiring or the mat itself)
Cure:
1) Try swapping the mat with another mat to verify this failure.
2) Call for assistance.