Technical specifications (din-rail controller) – Pinnacle Systems STTS User Manual
Page 9
3
TECHNICAL SPECIFICATIONS (Din-Rail controller)
Power:
24VDC +/- 15% @ 7 Watts maximum
Fuse Rating:
F1: 1A fuse
Max # of Mats:
Up to 4 separate mat inputs
Total Response
Time:
35 mSec/mat input
Outputs:
Safety
: 2 N.O. outputs (open when RED)
5A@30vdc resistive
Auxiliary
: N.O. or N.C. with common
5A@30vdc resistive
Fault
: N.O. (open when fault or no power)
5A@30vdc resistive
NOTE: Relay current rating is de-rated by ½ for inductive loads and again
by ½ for temperatures approaching 50C
Zone Reset
Inputs:
1 input for N.O. push button for manual resetting located on front of DIN-rail
Controller or optional Remote Status Display (RSD)
Settings:
Jumpers to select manual or automatic reset, up to four mats, fault reset, and
external relay checking
Indicators:
Internal:
+5V – Yellow LED’s (1)
Relays – Green LED’s (4)
+12V – Red LED (1)
20v – Green LED (1)
External:
4 Yellow LED's (1 per mat input)
Yellow LED on = standing on mat
Yellow LED flashing = Fault with
mat/circuitry
Red/Green LED’s
Green LED on = Relays energized
Red LED on = Relays de-energized
Red LED flashing = Relay fault
Dimensions:
Overall: 5.9” length x 2.9” wide x 4.3” height
DIN-rail:
35mm
Tolerance:
+- 0.10 inches / 02.5 cm
Environmental:
0 to 50C
Installation category I
Pollution degree 2
Altitude: up to 2000 meters
Humidity of 80% up to 31
C decreasing linearly to 50% humidity at 40
C
Indoor use
No cleaning is required.
The unit shall be supplied by a SELV source in accordance with CSA 1010.1 Annex H