JUMPER SETTINGS (metal box controller)
Computer Board:
S5
O O O O O O O O
BOTTOM
O O O O O O O O TOP
1 2 3 4 5 6 7 8
SHUNT(S)
DEFINITION
USAGE ( 1= JUMPER ON PINS)
1,2,3
# of mats in zone 1
1 MAT = 0,0,0 2 MATS = 1,0,0 3 MATS = 0,1,0
4 MATS = 1,1,0 5 MATS = 0,0,1 6 MATS = 1,0,1
7 MATS = 0,1,1 8 MATS = 1,1,1
4,5,6
# of mats in zone 2
0 MAT = 0,0,0 1 MAT = 1,0,0 2 MATS = 0,1,0
3 MATS = 1,1,0 4 MATS =0,0,1 5 MATS = 1,0,1
6 MATS = 0,1,1 7 MATS = 1,1,1
7,8
# of mats in zone 3
0 MAT = 0,0 1 MAT = 1,0
2 MATS = 0,1 3 MAT =1,1
Computer Board:
S1
O
AUX O O
EXT
O O
MAN O O
SHUNT(S)
DEFINITION
USAGE
S1
Fault reset
(Push Button)
Resets fault codes (tries to re-initialize unit)
JP6-AUX
N/A
Not used at this time
JP6-EXT
External relay checking active
for all zones used
E=Ext. relay checking
Apply jumper to activate function (message display
will add an E (ok E) to indicate you have selected
this function)
JP6-MAN
Manual / Automatic reset for
all zones
M = Manual reset
Jumper forces manual push-button to re-energize
zone relays
(message display will add an M (ok M ) to indicate
you have selected this function)