procedure may be required if the password is forgotten or the configurations are forgotten.

Power on MB5000 and wait for at least 1 minute till the device boots up and work in a

stable status, press and holds the RELOAD button for about 20 seconds, until all the

indicator lights change to amber. Then release RELOAD button, and press reset button to

reboot MB5000, the factory default network values are restored. Please refer Table 6-1 for

the factory default value.

Warning:

If you press and hold the RELOAD button for more than 10 seconds

immediately after the MB5000 is power on or reset, the MB5000 will enter into

Force Reload Procedure. The software in the MB5000 will be erased. You will

have to download software into MB5000 to make it work again.

Forced Reload Procedure

Use this procedure to force the MB5000 back to default network configuration values and

download new MB5000 software. This procedure may be required when the current

MB5000 software is missing, corrupted or needs to be upgraded.

Download procedure

1. Prepare you TFTP server. TFTP server is a computer with TFTP server software

running. TFTP server can be freely downloaded from

www.solarwinds.net

.

You

can also search other TFTP servers from Internet if you like.

2. To download the MB5000 Software, you will need an Ethernet connected to the

computer on which the TFTP server resides. This can be any computer on the

LAN, or connected to the MB5000’s “LAN” port with a “crossover” Ethernet cable.

3. After force reload, MB5000's IP will be set to 172.16.0.1 by default, and MB5000

will login the TFTP server with IP address “172.16.0.2” to download software

named “firmware.bin” by default. So please change the IP address of TFTP

server to 172.16.0.2, and change the MB5000 software name to firmware.bin,

put it in the directory of TFTP server root.