Accent Light Electrical Connection

Make sure power to the heater has been turned off prior to installation (disable the breaker).

Do not connect 110-120 VAC to the gas control valve or the on/off circuit on this fireplace.

The electrical line must be installed by a qualified installer and must meet all local codes.

The optional accent light requires a 110v circuit wired through a junction box to the fireplace.
See the illustration below for details.

Junction Box

(not supplied)

Insulated Wire (Romex)

Do not route the wires over the top

of the fireplace.

Power Supply

(110v ac)

Cover Plate on Control Box

(see instructions below)

Rheostat (included)

Cover Plate (included)

Knob (included)

Wiring Schematic

Rheostat Junction Box

Accent Lights

Power Supply

Hot

(black)

Common

(white)

Ground

(green)

Hot

(black)

Common

(white)

Ground

(green)

Fireplace Junction Box

Accent

Light

Molex

Connector

The wiring for the accent light is best installed

prior to drywall installation around the fireplace.

All electrical connections must be made by a

qualified installer and must meet all local codes.

Remove one of the knock-outs on the cover

plate and pass the wiring through the cover

plate (use the romex connector included with

the accent light). Attach the hot and common

wire from the accent light switched power

supply to the black and white wire leading from

the molex connector. Attach the ground wire to

the grounding tab on the receptacle.

Fireplace Power Supply

(attached to receptacle)

Control Box

Cover Plate

Romex

Connectors

Accent Light Switched

Power Supply