Installation

(for qualified installers only)

37

© Travis Industries

4090807

100-01193_003

Non-Combustible Facing

Non-combustible facing on the front of the fireplace must extend a minimum 17-1/4” from the
top of the glass frame. Above 17-1/4” combustibles may be used, but may not protrude more
than 3/4” from the non-combustible facing. Any combustible that protrudes more than 3/4” is
considered a mantel and must meet mantel clearances.

Non-combustible facing on the front of the fireplace must extend a minimum 6-1/2” to each
side of the glass frame. Beyond 6-1/2” combustibles may be used, but may not protrude more
than 3/4” from the non-combustible facing. Any combustible that protrudes more than 3/4” is
considered a side wall and must maintain the 11” side wall clearances.

The maximum depth for non-combustible facing is 6” (includes the cement board).

Combustible Material

(drywall, etc.)

Fiber Board

Fireplace

Glass Frame

17-1/4” Min.

50” Min.

(from base of fireplace)

Non-Combustible Facing

(tile, rock, marble, etc.)

Figure 26