Installation, Side view, For qualified installers only) – Avalon Firestyles 1080 CF Installation User Manual

Page 35: Hearth requirements – recessed hearth

Advertising
background image

Installation

(for qualified installers only)

35

© Travis Industries

4090807

100-01193_003

Hearth Requirements – Recessed Hearth

A hearth is not required if raised 6” above the flooring surface.

NOTE: Make sure to accommodate the flooring surface - this

distance must be measured from the top of carpeting or other

flooring material.

WARNING:

We recommend a hearth to protect the flooring

surface from discoloration or other negative

impact from the heater, especially if it is near the

minimum raised height.

Min. 6”

Side View

Fireplace

NOTE: When building a raised fireplace, consider the facing

material below the fireplace. If using tile, you may wish to

make the platform a suitable height for un-cut tile. For

example, if using 12” tile, make the platform 10-1/2” tall (10”

section of framing + 1/2” plywood).

1-1/2”

Cement Board

Plywood (OSB, etc.)

Framing

Sub-Floor

Minimum 6” to top of

flooring surface

(carpet, etc.)

Carpet

Figure 24

Advertising