Installation – Avalon Firestyles 564 SS Gas Installation User Manual

Page 13

Advertising
background image

Installation

(for qualified installers only)

1 3

© Travis Industries

4 0 7 0 6 2 0

100-01188_000

Minimum Framing Dimensions - Rear Vent Configuration

24-1/4"

36-1/2"

33-1/2"

16-1/2"

Route the

electrical line to

a position to the

left rear of the

fireplace.

Vent Clearances (8" dia. Vent):

1" to the sides, 1" below, and 4" above

the vent to combustibles.

Included Firestop (required)

Part # 250-00747

Center of Rear Vent

HINT: place the fireplace so the center

line is at least 5" from both vertical framing

members at the rear (this allows the vent

to pass through the framing without

modfications)

The on/off switch/thermostat wire (if

used) should be routed to a location

near the right front of the fireplace.

Minimum 38” Fireplace

Enclosure Height

19-1/4"

32-1/2"