3 8

Installation

(for qualified installers only)

Travis Industries

4 0 7 0 6 2 0

100-01188_000

Thick Facing Installation (stone, brick, or other non-combustible over 1" thick)

If using a Fireplace Xtrordinair (FPX) arched face, see "Thick Facing with a Fireplace Xtrordinair Arched

Faces" on page 39.

Do not install masonry (or other

material) in front of the

fireplace. This area must remain

open to install the face.

FRONT VIEW

Masonry Line

Hearth Line

Drywall

Fireplace

Drywall

Framing

Nailing Bracket

Masonry

TOP VIEW - Protruding Masonry

Fireplace

Drywall

(or cement board, etc.)

Framing

NOTE: The nailing brackets are not used for this type

of installation - secure the fireplace to the floor with

the brackets along the base of the fireplace.

Masonry

TOP VIEW - Recessed Masonry

29-1/4”

1”

36-1/4”

Floor-Mounted Fireplaces or Raised Hearths:

Build the hearth 1” (max.) above the base of the

fireplace. The fireplace may be raised to

accommodate thicker hearth materials.

Raised Fireplaces:

Masonry is installed 1” (maximum)

above the base of the fireplace.

Masonry Line

Masonry Line