2 8 installation, For qualified installers only) – Avalon Firestyles 564 SS Gas Installation User Manual

Page 28

Advertising
background image

2 8

Installation

(for qualified installers only)

Travis Industries

4 0 7 0 6 2 0

100-01188_000

Rear Vent Configuration with Horizontal Termination (with vertical
rise)

The termination must fall within the shaded area shown in the chart. Use the indicated restrictor and
diffuser positions.

Up to four elbows (45

°

or 90

°

) may be used.

Only one horizontal elbow may be used.

5 feet

0 feet

0 feet

5 feet

0 feet

20 feet

20 feet

5 feet

10 feet

5 feet

10 feet

0 feet

15 feet

20' (max)

10 feet

15 feet

15 feet

20' (max)

10 feet

15 feet

22' (max)

22' (max)

Exhaust Restrictor # 6

Intake Restrictor # 2
Diffuser Position # 2

Exhaust Restrictor # 2
Intake Restrictor # 1 (stock)

Diffuser Position # 1 (stock)

Exhaust Restrictor # 4

Intake Restrictor # 2
Diffuser Position # 2

This is considered a horizontal

elbow (it does not matter

whether it turns right or left).

It may be a 90° or 45° elbow.

This is considered a

vertical elbow

Horizontal length is calculated by adding

both lengths of horizontal run

(Horizontal Length = H1 + H2).

H1

H2

Advertising
This manual is related to the following products: