Mantel Requirements

The illustration below details mantel clearances and maximum mantel depth.

Any material that protrudes more than 3/4” from the non-combustible facing is considered a mantel
and must meet the mantel requirements.

Mantel (combustilbe or non-combustible)

Combustible mantel columns (legs) that

protrude more than 3/4” from the glass

frame must meet the sidewall clearance (1”).

If they protrude 3/4” or less, they may be

placed directly to the side (but not in front) of

the fireplace.

Non-combustible mantel columns do not

have a minimum clearance.