Installation, Side view top view, For qualified installers only) – Avalon Firestyles 564 SS Gas Installation User Manual

Page 43

Advertising
background image

Installation

(for qualified installers only)

4 3

© Travis Industries

4 0 7 0 6 2 0

100-01188_000

Installation Example - Build-In with Horizontal Termination

The framing, facing, and other building materials depicted below are for example only. Refer to local
building codes for framing, facing, and insulating requirements in your area.

Side View

Top View

See “Vent Termination”

for full requirements.

4” Section*

Firestop

NOTE FOR 2 x 4 EXTERIOR WALLS:

When installed with a 2x4 exterior wall, the

termination may not fit flush against the exterior

wall. You may wish to place framing around the

termination to fill the gap.

SIDE OF FIREPLACE

Horizontal Termination*

* Travis Ind. MIn. Vent Kit (SKU 98900168)

Includes a 4” section and horizontal termination.

NOTE: If required to use drywall inside

the firebox enclosure, make sure to alter

the framing accordingly.

NOTE:

1/2” Clearance to sides

and back of fireplace.

Insulation

Drywall

Optional Tile

Drywall

Optional Tile

The cap overlaps the exterior

siding by 1/16” - you may wish to

make a flashing for this area.

Advertising
This manual is related to the following products: