Rear Vent Configuration with Horizontal Termination (no vertical rise)

The termination must fall within the shaded area shown in the chart. Use the indicated restrictor and
diffuser positions.

Optional 45° Elbow

Termination

See the charts below to
determine maximum vent

3 feet

0 feet

0 feet

4' (max)

• Exhaust Restrictor # 0 (stock)
• Intake Restrictor # 1 (stock)
• Diffuser Position # 1 (stock)

Vent with No 45° Elbow

3 feet

0 feet

0 feet

2' (max)

Vent with 1 45° Elbow

• Min. 4" Horizontal Section
• Max. 24" Horizontal Section(s)

• Min. 4" Horizontal Section
• Max.48" Horizontal Section(s)

• Exhaust Restrictor # 0 (stock)
• Intake Restrictor # 1 (stock)
• Diffuser Position # 1 (stock)