Installation, Packing list, Additional items required – Avalon Firestyles 564 SS Gas Installation User Manual

Page 7: Installation overview, Recommended installation procedure, For qualified installers only)

Advertising
background image

Installation

(for qualified installers only)

7

© Travis Industries

4 0 7 0 6 2 0

100-01188_000

Packing List

Propane Conversion Kit

Log Set

Wall Switch with Wire (see page

21 for details)

Firestop (sku 250-00747)

Additional Items Required

Direct Vent

Gas Line Equipment (shutoff valve, pipe, etc.)

Electrical Equipment (min. 14 gauge, grounded line)

Installation Overview

All requirements below must be met.

See the section

"Approved Vent

Configurations"

See the section

"Electrical Connection"

See the section

"Mantel Requirements"

Insulation must not fill

the 1/2" clearance

around the back and

sides of the fireplace.

See the section

"Vent Requirements"

See the section "Minimum

Framing Dimensions"

Drywall

Top Vent
Configuration

Rear Vent
Configuration

See the section

"Gas Line Installation"

1" Min.

Side
Wall

See "Optional Non-

Combustible Facing"

Drywall

See "Optional Non-

Combustible Hearth"

Nailing Brackets

Required Travis

Firestop (sku

250-00747)

Recommended Installation Procedure

1

Frame the opening for the fireplace. Make sure to allow for vent installation.

2

This fireplace is designed to accommodate 1/2" or 5/8" drywall (see "Nailing Brackets" on page 15
for details). Secure the fireplace to the framing.

3

Install the vent, gas line and electrical hook-up.

4

Install the wall switch (see page 21) or thermostat (if applicable).

5

Install the drywall.

6

Install the hearth (if applicable).

7

Install the facing (if applicable).

8

Install the mantel (if applicable).

9

Finalize the installation (see page 44) and install the grill or face.