6 2

Optional Equipment

(for qualified installers only)

Travis Industries

4 0 7 0 6 2 0

100-01188_000

3.

Attach the wiring and rheostat assembly following the directions below.
N O T E

: You may need to cut or adjust some of the lock ties on the wiring harness.

N O T E

: Make sure wiring does not contact blower impellers or any hot surfaces. Use lock-ties if

necessary.

SNAP DISC

BL

OWER

Attach one black and

white wire to each

blower (orientation does

not matter).

Attach the wires labeled

SNAP DISC to the

snap disc (orientation

does not matter).

These wires are for the optional
remote control. Place them behind
the gas control valve.

Plug the power cord into the

receptacle at the rear of the fireplace.

VALVE-RED/BRN

SOLENOID

-BLU

Attach the rheostat assembly to the

fireplace with the two black screws.

4.

Turn on power to the fireplace.
N O T E

: To test the blower without turning on the fireplace, use a jumper wire to connect the two snap

wires together (turn off power prior to connecting the jumper wire).